Product Details:
|
Application: | Uninterruptible Power Supplies | Mounting Type: | PCB Mounting |
---|---|---|---|
Principle: | Null Balance | Standard: | High Precision |
Product Name: | Hall Effect Current Sensor | Operating Temperature: | -40~+85 |
High Light: | hall effect linear current sensor,hall effect current sensor 100a |
TBC-PX5 Hall Effect Current Transducer DC AC Or Pulsed Current Measurement
TBC-PX5 series current sensor is two closed loop device based on the measuring principle of the hall effect,
with a galvanic isolation between primary and secondary circuit. It has strong anti-jamming ability and provides accurate electronic measurement of DC, AC or pulsed currents.
Electrical data(Ta=25℃±5℃) |
Type Parameter |
TBC03 PX5 |
TBC05 PX5 |
TBC10 PX5 |
TBC15 PX5 |
TBC20 PX5 |
TBC25 PX5 |
TBC30 PX5 |
TBC50 PX5 |
Unit |
Rated input (Ipn) |
3 | 5 | 10 | 15 | 20 | 25 | 30 | 50 | A |
Measuring range(Ip) | 6.6 | 11 | 22 | 33 | 44 | 55 | 66 | 110 | A |
Turns ratio(Np/Ns) | 4: 5:1500 | 3:1500 | 2:1000 | 2:1500 | 1:1000 | 1:1250 | 1:1500 | 1:1000 | |
Inside resistance |
100±0.1% | 100±0.1% | 50±0.1% | 50±0.1% | 50±0.1% | 50±0.1% | 50±0.1% | 20±0.1% | Ω |
Rated output | @ Ip=Ipn, 1.0±0.5%FS | V | |||||||
Supply voltage | +5±5% | V | |||||||
Power consumption | ≤20+IpX(Np/Ns) | mA | |||||||
Zero voltage |
@ Is=0 2.5±0.5% | V | |||||||
Zero drift |
@ -40~+85℃ ≤±0.5 | mV/℃ | |||||||
Linearity | @ Ip=0-±Ipn ≤0.1 | %FS | |||||||
Response time | @ Ip=Ipn, 50 A/µS ,10%-90% <500 | ns | |||||||
Bandwidth | @ -1dB 0—100 | KHZ | |||||||
Galvanic isolation | @ 50/60HZ, AC, 1min 5.0 | KV |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
DC motor drives
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
Directions for use |
When the current will be measured goes through a sensor, the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor).
Custom design in the different rated input current and the output voltage available.
Standards
General date |
Value | Unit | Symbol | |
Operating temperature | -40 to +85 | ºC | TA |
Storage temperature | -40 to +125 | ºC | TS |
Mass(approx) | 18 | g | M |
Characteristics chart |
Pulse current signal response characteristic Effects of impulse noise