Product Details:
|
Application: | Inverter | Mounting Type: | PCB Mounting |
---|---|---|---|
Principle: | Null Balance | Standard: | High Precision |
Product Name: | Hall Effect Current Sensor | Operating Temperature: | -40~+85 |
High Light: | PCB Mount Hall Current Transducer,Photovoltaic Hall Current Transducer,Electrochemical Hall Effect Current Transducer |
PCB Mount Hall Effect Current Transducer Hall Effect Dc Current Sensor
TBC-LSR508 series current sensor is closed loop device based on the measuring principle of the hall effect,with a galvanic isolation between primary and secondary circuit. It has strong anti-jamming ability and provides accurate electronic measurement of DC, AC or pulsed currents.
Electrical data(Ta=25℃±5℃) |
Type |
TBC06 |
TBC10 |
TBC15 |
TBC20 |
TBC25 |
TBC30 |
TBC32 |
TBC40 |
TBC50 |
Unit |
Rated input (Ipn) |
6 | 10 | 15 | 20 | 25 | 30 | 32 | 40 | 50 | A |
Measuring ran(Ip) |
±15 | ±25 | ±37.5 | ±50 | ±62.5 | ±75 | ±80 | ±100 | ±125 | A |
Turns (Np/Ns) |
1:1200 | 1:1000 | 1:1125 | 1:1000 | 1:1250 | 1:1125 | 1:1200 | 1:1000 | 1:1000 | T |
Internal resister | 40.0 | 20.0 | 15.0 | 10.0 | 10.0 | 7.5 | 7.5 | 5.0 | 4.0 | Ω |
Rated output |
@ Ip=±Ipn ±0.8±0.5% | V | ||||||||
Output rsistance |
≤20 | Ω | ||||||||
Size of primary pins |
□ 6.28 ×1.0 | mm | ||||||||
Supply voltage |
+5±5% | V | ||||||||
Power consumption |
≤15+Ip/Ns | mA | ||||||||
Reference voltage |
+2.5±0.5%(Output) | V | ||||||||
Vrefinternal resist resistor |
200 | Ω | ||||||||
Vref external range resistor |
2.0-2.8(Input) | V | ||||||||
Zero voltage | @ Ip=0 +2.5±0.5% | V | ||||||||
Offset drift |
@ -40~+105℃ ≤±0.05 | mV/℃ | ||||||||
output drift | @ -40~+105℃ ≤±0.05 | mV/℃ | ||||||||
Linearity |
@ Ip=0-±Ipn ≤0.1 | %FS | ||||||||
Total accuracy |
≤±1.0 | % | ||||||||
di/dt |
>50 | A/µS | ||||||||
Response time |
@ Ip=Ipn, 50 A/µS ,10%-90% <1.0 | µS | ||||||||
Bandwidth |
@ -1db DC~100 | KHZ | ||||||||
Galvanic isolation |
@ 50HZ,AC,1min 3.0 | KV |
Applications
Variable speed drives
Photovoltaic
Frequency converter
Electrochemical
Electric machine control
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
Directions for use |
When the current will be measured goes through a sensor ,the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor).
Custom design in the different rated input current and the output voltage available.
Standards
General date |
Value | Unit | Symbol | |
Operating temperature | -40 to +85 | ºC | TA |
Storage temperature | -40 to +125 | ºC | TS |
Mass(approx) | 12 | g | M |
Characteristics chart |
Pulse current signal response characteristic Effects of impulse noise
Contact Person: Ms. Suki
Tel: 13951079826
Fax: 86-025-84643985