Send Message
Home ProductsHall Effect Transmitter

4800A Hall Effect Current Sensor UPS Open Loop Current Sensor

I'm Online Chat Now

4800A Hall Effect Current Sensor UPS Open Loop Current Sensor

4800A Hall Effect Current Sensor UPS Open Loop Current Sensor
4800A Hall Effect Current Sensor UPS Open Loop Current Sensor

Large Image :  4800A Hall Effect Current Sensor UPS Open Loop Current Sensor

Product Details:
Place of Origin: CHINA
Brand Name: TOKEN
Certification: CE;ROHS
Model Number: TKC-KD
Payment & Shipping Terms:
Minimum Order Quantity: 10pcs
Price: Price Reconsideration
Packaging Details: Little Carton Size:34*23*21CM;240pcs/Carton ;Large Carton Size:48*37*26CM;480pcs/Carton
Supply Ability: 2.2K pcs per month

4800A Hall Effect Current Sensor UPS Open Loop Current Sensor

Description
Product Name: Hall Effect Transmitter Operating Temperature: _40℃~+85℃
Color: Black Application: Electrochemical
Frequency: 40~1000hz Response Time: ≤200mS
High Light:

BMS Hall Effect Current Sensor

,

4800A Hall Effect Current Sensor

,

UPS Open Loop Current Sensor

Electrochemical Hall Effect Transmitter 40~1000hz Frequency Black

 

TKC-KD series current sensor is dismountable, which is a open loop device based on the measuring principle of the hall effect , with a galvanic isolation between primary and secondary circuit . It can measure AC pulse and various irregular wave current in electrical isolation conditions.

 

Electrical data(Ta=25℃±5℃)

 

Type

Parameter

TKC100KD TKC300KD TKC500KD TKC800KD TKC1000KD TKC2000KD

 

Unit

 

Ratedcurrent(Ipn AC)

100 300 500 800 1000 2000 A

 

Measuring range(Ip AC)

150 450 750 1200 1500 2500 A

Rated output (DC)
@Ip=±Ipn ±5±1% V

Supply voltage
±15 ±5% V

 

Power Consumption

+35,-20 mA

Offset voltage
@Ip=0 ±30 mV

Offset drift
@ -40~+85℃ ≤±1 mV/℃

output drift
@ -40~+85℃ ≤±1 mV/℃

 

Linearity

@Ip=0-±Ipn ≤0.5 %FS

 

Response time

≤200 mS

Bandwidth
@-3dB 40~6000 HZ

 

Galvanic isolation

@ 50HZ,AC,1min 5.0 KV
 

 

Applications

 

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

 

Mechanical dimension(for reference only)

4800A Hall Effect Current Sensor UPS Open Loop Current Sensor 0

 

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm

 

Directions for use

 

When the current will be measured goes through a transmitter, The voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the transmitter).

The output amplitude of the transmitter can be adjusted according to users’ requirements.

Custom design in the different rated input current and the output voltage available.

 

Standards

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date

 

  Value Unit Symbol
Operating temperature -40 to +85 ºC TA
Storage temperature -40~+125 ºC TS
Mass(approx) 68 g M

 

 

Characteristics chart

Effects of impulse noise
4800A Hall Effect Current Sensor UPS Open Loop Current Sensor 1

Contact Details
Nanjing Token Electronics Science&Technology Co., Ltd.

Contact Person: Ms. Suki

Tel: 13951079826

Fax: 86-025-84643985

Send your inquiry directly to us (0 / 3000)