Product Details:
|
Application: | Uninterruptible Power Supplies | Mounting Type: | PCB Mounting |
---|---|---|---|
Principle: | Null Balance | Standard: | High Precision |
Product Name: | Hall Effect Current Sensor | Operating Temperature: | -40~+85 |
High Light: | hall effect high current sensor,closed loop current transducer |
UL94-V0 Closed Loop Current Transducer For Uninterruptible Power Supplies
The TBC-SYHA/SYHWA series current sensor is a two-closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It has strong anti-jamming ability and provides accurate electronic measurement of DC, AC or pulsed currents.
Electrical data(Ta=25℃±5℃) |
Type
Parameter |
TBC05SYHA /SYHWA |
TBC7.5SYHA /SYHWA |
TBC10SYHA /SYHWA |
TBC15SYHA /SYHWA |
TBC20SYHA /SYHWA |
TBC25SYHA /SYHWA |
TBC30SYHA /SYHWA |
TBC50 SYHA |
Unit |
Rated input(Ipn) |
5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 50 | A |
Measuringrange(Ip) |
15 | 22.5 | 30 | 45 | 60 | 75 | 90 | 125 | A |
Size of input pins |
ø 0.6 | ø 0.8 | ø 0.8 | ø 1.0 | ø 1.4 | ø 1.4 | ø 1.6 | □1.6 ×1.5×2 | mm |
Turns ratio(Np/Ns) |
5:1250 | 3:1125 | 3:1500 | 2:1500 | 1:1000 | 1:1250 | 1:1500 | 1:2500 | |
Measuring resistance range |
100-300 | Ω | |||||||
Rated output (Isn) |
@ Ip=±Ipn ±20±0.5% | mA | |||||||
Supply voltage |
±15±5% | V | |||||||
Power consumption |
20+IpX(Np/Ns) | mA | |||||||
Zero current |
@ Ip=0 ≤±0.2 | mA | |||||||
Offset drift |
@ -40~+85℃ ≤±0.5 | mA | |||||||
Linearity |
@ Ip=0-±Ipn ≤0.1 | %FS | |||||||
Response time |
@ Ip=Ipn, 50 A/µS ,10%-90% <1.0 | μS | |||||||
Galvanic isolation |
@ 50HZ,AC,1min 5.0 | KV |
Applications |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. Secondary pin size and tolerance: width:0.5±0.1mm;thickness:0.25±0.05mm
3. General tolerance ±1mm.
Directions for use |
When the current will be measured goes through the primary pin of a sensor, the current will be measured at
the output end. (Note: The false wiring may result in the damage of the sensor).
Custom design in the different rated input current and the output current are available.
Standards
UL94-V0.
EN60947-1:2004
IEC60950-1:2001
EN50178:1998
SJ 20790-2000
General date |
Value | Unit | Symbol | |
Operating temperature | -40 to +85 | ºC | TA |
Storage temperature | -40 to +125 | ºC | TS |
Mass(approx) | 11 | g | M |
Characteristics chart |
Pulse current signal response characteristic Effects of impulse noise
Contact Person: Ms. Suki
Tel: 13951079826
Fax: 86-025-84643985